🎒 SchoolNEW 💡 Suggest

Gearbox service factor check

Check whether a gearbox suits the application: output torque × service factor compared with the catalogue rated torque, with margin and actual factor. The service factor fB accounts for shocks, operating hours per day and starts per hour. The calculator is free and shows the formula, the working and a numerical example, with no sign-up.

Results

Indicative results: always verify with a qualified technician and the applicable standards. Legal notice

Step-by-step calculation with your values

    Formulas

    T_c = T_2 \cdot f_B
    f_{B,r} = \frac{T_{2N}}{T_2}
    k = \frac{T_{2N}}{T_c}
    m = \left(\frac{T_{2N}}{T_c} - 1\right) \cdot 100

    How it is calculated

    The service factor fB accounts for shocks, operating hours per day and starts per hour. The gearbox is fine if T2N ≥ T2·fB, i.e. the actual factor T2N/T2 is at least fB. Rough values: uniform load up to 10 h/day ≈ 1.0–1.2; moderate shocks (unevenly loaded conveyors, palletizers) ≈ 1.25–1.5; heavy shocks or many starts ≈ 1.75–2.0. Exact values are in the manufacturer's tables. Indicative values: the gearmotor manufacturer's data and instructions apply for the final selection.

    Results are indicative: for real projects and installations always check applicable standards and a qualified professional.

    Example

    With the values: Torque required by the load (output) = 92 N·m; Application service factor fB = 1.4; Catalogue rated torque T2N = 150 N·m — you get:

    • Design torque T2·fB: 128.8 N·m
    • Actual service factor T2N/T2: 1.63
    • Check (≥ 1 = gearbox adequate): 1.16
    • Margin on catalogue torque: 16.5 %

    Frequently asked questions

    Which formula does the “Gearbox service factor check” calculator use?

    The service factor fB accounts for shocks, operating hours per day and starts per hour. The gearbox is fine if T2N ≥ T2·fB, i.e. the actual factor T2N/T2 is at least fB. Rough values: uniform load up to 10 h/day ≈ 1.0–1.2; moderate shocks (unevenly loaded conveyors, palletizers) ≈ 1.25–1.5; heavy shocks or many starts ≈ 1.75–2.0. Exact values are in the manufacturer's tables. Indicative values: the gearmotor manufacturer's data and instructions apply for the final selection.

    Is FunConvert free?

    Yes. Every converter and calculator is free, with no sign-up and nothing to install. Calculations run in your browser.

    What do you think?

    Your rating